Junction Rivers (JRBATT1)

BESS · Junction Rivers Pty Ltd · Storage - Battery

AEMO: removed NSW1 Other - Other NEM data · 30 days
200/800 MW
Registered nameplate capacity / storage
Est. SRMC
$0.00/MWh
Key information
Capacity
200 MW / 800 MWh

AEMO status removed
Project status (AI)

Region NSW1
Coordinates

DUID JRBATT1
Owner Junction Rivers Pty Ltd
Commissioned Oct 2029
Expected closure 2025
Closure date
Technology Storage - Battery
Fuel Other - Other
Battery OEM
Battery platform / chemistry
Inverter OEM
Inverter / PCS model
Stats window
16 May 2026 05:30 → 15 Jun 2026 05:30 AEST

Dispatch & revenue

16 May 2026 05:30 → 15 Jun 2026 05:30 AEST

No dispatch data for DUID JRBATT1 in this period.

Financial overview

2026 real AUD. Monetary values are CPI-adjusted to 2026 real Australian dollars. Greenfield capex uses AEMO benchmarks when plant-specific cost is unknown.
Type
Battery (BESS)
Capacity
200 MW / 800 MWh
Revenue (× MLF) (stats)
See dispatch stats link above
Est. SRMC
$0.00/MWh
Capex total (greenfield)
$2,109.70M

Shown in table
$2,109.70M (2026 real AUD)

Reported / source value
$2,000.00M (2024 nominal)
Adjusted to 2026 real AUD using Australian CPI (All Groups).

How this was derived
Official project website gives a headline project investment of $2 billion+ for the overall wind and storage precinct.

Reference
Junction Rivers (medium confidence)
Source recorded 08 Jun 2026

Capex refurbishment
Capex / MWh storage derived
$2,637,131

Shown in table
$2.64M (2026 real AUD)

Reported / source value
$2.50M (2024 nominal)
Adjusted to 2026 real AUD using Australian CPI (All Groups).

Fixed OPEX (annual)
$1.48M

Shown in table
$1.48M (2026 real AUD)

Reported / source value
$1.40M (2024 nominal)
Adjusted to 2026 real AUD using Australian CPI (All Groups).

How this was derived
Annual fixed O&M computed from the benchmark and registered capacity.

Reference
2023 Cost and Technical Parameters Review_Final Report (high confidence)
Source recorded 08 Jun 2026

Fixed OPEX / MW-yr
$7,384

Shown in table
$7.4k (2026 real AUD)

Reported / source value
$7.0k (2024 nominal)
Adjusted to 2026 real AUD using Australian CPI (All Groups).

How this was derived
Aurecon/AEMO benchmark for a 200 MW BESS co-located with a large renewable installation.

Reference
2023 Cost and Technical Parameters Review_Final Report (high confidence)
Source recorded 08 Jun 2026

Variable OPEX / MWh
$0.00

Shown in table
$0.00 (2026 real AUD)

Reported / source value
$0.00 (2024 nominal)
Adjusted to 2026 real AUD using Australian CPI (All Groups).

How this was derived
Aurecon did not specify a variable O&M value for BESS; nil is a reasonable simplifying assumption.

Reference
2023 Cost and Technical Parameters Review_Final Report (medium confidence)
Source recorded 08 Jun 2026

Fuel cost / GJ
Heat rate GJ/MWh

Confidence: medium · Status: ai estimated · Capex basis: reported · AI checked 08 Jun 2026

Notes
Plant-specific public source states Junction Rivers is a '$2 billion+' wind energy and storage project; the 200 MW/800 MWh battery is part of the wider project, so capex is allocated proportionally to the battery share using the registered 200 MW / 800 MWh battery size. This is an inferred allocation, not a directly stated battery-only cost. AEMO/Aurecon battery benchmark for a 200 MW / 800 MWh (4-hour) co-located BESS implies about AUD 269.4m EPC and AUD 7,000/MW-year fixed O&M in 2024 terms, but the project-specific reported headline project cost takes precedence for capex under the user's hierarchy.

Sources