Warning: session_start(): Session cannot be started after headers have already been sent in /home/nemstats/web/nemstats.com.au/public_html/lib/admin_auth.php on line 29

Stubbo Solar Farm (STUBSF1)

Solar · ACEN AUSTRALIA · Solar PV - Single axis tracking

In Commissioning NSW1 Solar - Solar NEM data · 24 hours
202 MW
Registered nameplate capacity
24 hours revenue
$3.8k
Capacity factor
2.9%
Revenue / MWh
$26.97
Est. SRMC
$0.25/MWh
MLF
0.9429

Stats window 03 Jun 2026 15:15 → 04 Jun 2026 15:15 AEST

Key information
Capacity
202 MW
Status In Commissioning
Lifecycle Other
Region NSW1
DUID STUBSF1
Owner ACEN AUSTRALIA
Commissioned Dec 2024
Expected closure 2073-07-02
Closure date
Technology Solar PV - Single axis tracking
Fuel Solar - Solar
Module OEM
Module / inverter supplier
Inverter OEM
Inverter model

Dispatch & revenue

03 Jun 2026 15:15 → 04 Jun 2026 15:15 AEST

Revenue (× MLF)
$3.8k
Dispatched
142.6 MWh
Available
87.9 MWh
Curtailed
MWh
Curtailment
0.0%
of available
MLF used
0.9429
end of period

Energy flow

Dispatch target (cleared) vs availability — 5‑minute intervals. NSW1 regional price (RRP) on right axis.

Revenue (× MLF)

Estimated $ per interval using regional RRP and MLF effective on each day.

Methodology & assumptions

  • Dispatch & availability — AEMO Next Day Dispatch UNIT_SOLUTION (5‑minute intervals). Intervention intervals excluded.
  • Regional pricedispatch_price RRP matched by settlement time and NEM region (from generator registry).
  • Revenue (× MLF) — cleared MW × (5/60 h) × RRP × MLF. Chart uses MLF effective on each interval’s date; summary total uses MLF as at the end of the selected period (same as the revenue list).
  • Curtailment — estimated economic curtailment when availability exceeds dispatch target: max(0, availability − cleared) × (5/60) MWh.
  • Not settlement — estimates only. AEMO settlement applies DLF, rebids, constraints, and other factors not modelled here.
MLF history (AEMO daily)
Effective fromMLF
2024-12-17 0.9422
2025-07-01 0.9429

Financial overview

2026 real AUD. Monetary values are CPI-adjusted to 2026 real Australian dollars. Greenfield capex uses AEMO benchmarks when plant-specific cost is unknown.
Type
Solar (tracking)
Capacity
202 MW
Revenue (× MLF) (stats)
See dispatch stats link above
Est. SRMC
$0.25/MWh
Capex total (greenfield)
Capex refurbishment
Capex / MW default
$1,300,000
Capex / MWh storage
Fixed OPEX (annual)
Fixed OPEX / MW-yr default
$20,000
Variable OPEX / MWh default
$0.25
Fuel cost / GJ
Heat rate GJ/MWh

Confidence: unknown · Status: needs review · Capex basis: unknown